30SXXXXX0

PAH, oil-in-water using UV fluorescence


enviroFlu-HC is the new generation of immersion sensors for measurement of oil-in-water. The used measuring principle of UV fluorescence is much more sensitive than the conventionally used infrared scattering or absorption method. This allows to determine even the slightest traces of PAH's, for
example in drinking water and cooling water condensates. Application areas include the petrochemical industry, leakage detection in cooling and wastewater streams as well as environmental monitoring. The devices enable both stationary use in shafts, flows or piping, and mobile use through an optional hand-held measuring instrument. An innovative coating reduces fouling of the optical measuring window and minimizes the maintenance.

Measurement technology

light source: Xenon flash lamp + filter (254 nm)

detector: Photo diode + filter (360 nm)

Measurement principleFluorescence
ParameterPAH, oil
Measurement range

enviroFlu-HC 500

PAH: 0...50 ppb, 0...500 ppb
Oil: 0...1.5 ppm, 0...15 ppm typical

enviroFlu-HC 5000

PAH: 0...500 ppb, 0...5000 ppb
Oil: 0...15 ppm, 0...150 ppm typical

Detection limitenviroFlu-HC 500 0.3 ppb
enviroFlu-HC 5000 0.5 ppb
Measurement accuracy± 5 % FS
Reproducibility≤ 0,5 % FS
Turbidity compensationNo
Data loggerNo
T100 response time≤ 10 s
Measurement interval≥ 5 s
Material

Housing: Stainless steel (1.4571/1.4404) or titanium (3.7035)

Head: POM black with synthetic quartz glass

Dimensions (L x Ø)311 mm x 68 mm ~ 12.2˝ x 2.6˝
Weight

stainless steel: ~ 2.7 kg ~ 6 lbs

titanium: ~ 1.9 kg ~ 4.2 lbs

Interface

digital: RS-232 (TriOS)

analog: 4...20 mA, 0...5 V

Power consumption≤ 3.5 W
Power supply12...24 VDC (± 10 %)
Maintenance effort≤ 0.5 h/month (typical)
Calibration/maintenance interval24 months
System compatibility Analog Out (0...5 VDC, 4...20 mA)
Warranty

1 year (EU: 2 years)

US: 2 years

Installation
Max. pressure

with SubConn: 30 bar ~ 435 psig

with fixed cable: 3 bar ~ 43.5 psig

in FlowCell: 1 bar, 2...4 L/min ~ 14.5 psig at 0.5 to 1 gpm

Deepsea version: 600 bar

Protection type

IP68

NEMA 6P

Sample temperature

+2...+40 °C

~ +36 °F to +104 °F

Ambient temperature

-5...+55 °C (2...+40 °C for specified accuracy)

~ +23 °F to +131 °F (~ 35,6 °F to 104 °F for specified accuracy)

Storage temperature

-20...+80 °C

~ -4 °F to +176 °F

Inflow velocity

0.1...10 m/s

~ 0.33 fps to 33 fps

Max. immersion depth

30 m with fixed cable ~ 98.43 ft with fixed cable

optional: 6000 m deepsea version optional: ~ 19685.04 ft deepsea version

Benefits

• Without sampling and preparation of test samples

• Real time sensor

• Without reagents

• High sensitivity and selectivity

• Optical window with nano coating

Applications

• Drinking water

• Wastewater

• Airports

• Cooling water

• Desalination plants

• Refineries

• Pipeline monitoring

• Bilge water monitoring

• Exhaust gas cleaning with approval for ship use

according to IMO regulation MEPC.184(59)