"HyQuest Solutions “HART to SDI-12 Interface”

The HyQuest Solutions „HART to SDI-12 Interface“ allows any 4-20mA HART device to be connected to an SDI-12 data logger providing the best accuracy available from the HART protocol.The Hartbeat is available in two models, HBT1 and HBT1 Plus.

Main Features

  • Dual SDI-12 and 4-20mA output Interface
  • LCD Display
  • Robust powder coated aluminium enclosure (IP65)
  • User selectable options
  • Power: +10V to +18 V DC
  • Reverse polarity protection.
  • Hart Interface +16V DC (Even when power source is +10 V )
  • Current limited to 30mA – in the event of a short circuit.
  • Uses Hart commands to retrieve info and also set configuration. (Allows connection of external Vega Connect Master by providing +16V DC power and no comms – DIP Sw selection)
  • Main SDI: SDI-12 (Conforms to SDI-12V1.3)
  • Extra SDI: Conforms to SDI-12 V1.3)
  • 4-20mA: As a sensor - Range configurable
  • User Selectable Options Internal DIP Switches (refer to instruction manual for details) MODEL HBT1P
  • Connection: Plug-in 6 way screw terminals and Plug-in 3,way screw terminals (refer to instruction manual for details).
  • Operating Temperature -400C to +700C
  • Environmental IP65
  • Dimensions 205mm x 100mm x 105mm (L x W x D)